Energy Performance Certificate

Flat 2, 54 Montpelier Road, BN1 3BA

EPC Report

Energy rating

Current: 39 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 46 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 70 Potential: 70
Field Value
LMK KEY 8809-0896-1829-8126-3513
ADDRESS1 Flat 2
ADDRESS2 54 Montpelier Road
ADDRESS3
POSTCODE BN1 3BA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-05-21
LOCAL AUTHORITY E06000043
CONSTITUENCY E14001130
COUNTY
LODGEMENT DATE 2019-05-22
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 493
ENERGY CONSUMPTION POTENTIAL 264
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 83
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 33
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 795
HEATING COST POTENTIAL 149
HOT WATER COST CURRENT 266
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 40
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 6.4
FLOOR HEIGHT 3.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 2, 54 Montpelier Road
LOCAL AUTHORITY LABEL Brighton and Hove
CONSTITUENCY LABEL Brighton Pavilion
POSTTOWN BRIGHTON
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-05-22 09:57:03
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 22124153
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew