Energy Performance Certificate

74, Cherry Road, PR8 3SE

EPC Report

Energy rating

Current: 49 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 35 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 80 Potential: 80
Field Value
LMK KEY 8807-8784-2429-1497-9563
ADDRESS1 74, Cherry Road
ADDRESS2
ADDRESS3
POSTCODE PR8 3SE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-05-18
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001463
COUNTY
LODGEMENT DATE 2016-05-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 468
ENERGY CONSUMPTION POTENTIAL 117
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 79
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 111
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 889
HEATING COST POTENTIAL 560
HOT WATER COST CURRENT 354
HOT WATER COST POTENTIAL 78
TOTAL FLOOR AREA 92
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 30
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 30% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 74, Cherry Road
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Sefton Central
POSTTOWN SOUTHPORT
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-05-19 07:57:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 41017298
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000002
Address display
Nation ew