Energy Performance Certificate

First Floor Flat, 5 Park Road, SS0 7PE

EPC Report

Energy rating

Current: 59 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 55 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 79 Potential: 79
Field Value
LMK KEY 8807-6505-1329-8377-4833
ADDRESS1 First Floor Flat
ADDRESS2 5 Park Road
ADDRESS3
POSTCODE SS0 7PE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Detached
INSPECTION DATE 2017-08-30
LOCAL AUTHORITY E06000033
CONSTITUENCY E14001501
COUNTY
LODGEMENT DATE 2017-08-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 327
ENERGY CONSUMPTION POTENTIAL 154
CO2 EMISSIONS CURRENT 2.9
CO2 EMISS CURR PER FLOOR AREA 58
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 521
HEATING COST POTENTIAL 245
HOT WATER COST CURRENT 89
HOT WATER COST POTENTIAL 90
TOTAL FLOOR AREA 50
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS First Floor Flat, 5 Park Road
LOCAL AUTHORITY LABEL Southend-on-Sea
CONSTITUENCY LABEL Southend East and Rochford
POSTTOWN WESTCLIFF-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-08-30 12:39:13
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display