Energy Performance Certificate

Green Garth, Ufford Place, Ufford, IP13 6DR

EPC Report

Energy rating

Current: 30 F | Potential: 55 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 F Current: 30 F 55 D Potential: 55 D

Environmental impact (CO₂)

Current: 26 | Potential: 45
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 45 Potential: 45
Field Value
LMK KEY 8803-9195-4129-6697-7433
ADDRESS1 Green Garth
ADDRESS2 Ufford Place
ADDRESS3 Ufford
POSTCODE IP13 6DR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 30
POTENTIAL ENERGY EFFICIENCY 55
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2017-04-11
LOCAL AUTHORITY E07000244
CONSTITUENCY E14001156
COUNTY
LODGEMENT DATE 2017-04-11
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 45
ENERGY CONSUMPTION CURRENT 327
ENERGY CONSUMPTION POTENTIAL 189
CO2 EMISSIONS CURRENT 11.8
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 7.4
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 1315
HEATING COST POTENTIAL 1063
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 137
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA More Than Typical
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 60
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 60% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.45
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Green Garth, Ufford Place, Ufford
LOCAL AUTHORITY LABEL East Suffolk
CONSTITUENCY LABEL Central Suffolk and North Ipswich
POSTTOWN WOODBRIDGE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-04-11 22:26:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100091400434
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew