Energy Performance Certificate

26, Avalon Close, NG6 9JW

EPC Report

Energy rating

Current: 60 D | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 D Current: 60 D 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 55 | Potential: 86
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 86 Potential: 86
Field Value
LMK KEY 8802-7694-5329-4907-8463
ADDRESS1 26, Avalon Close
ADDRESS2
ADDRESS3
POSTCODE NG6 9JW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 60
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-04-01
LOCAL AUTHORITY E06000018
CONSTITUENCY E14001411
COUNTY
LODGEMENT DATE 2016-04-01
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 86
ENERGY CONSUMPTION CURRENT 322
ENERGY CONSUMPTION POTENTIAL 89
CO2 EMISSIONS CURRENT 3.6
CO2 EMISS CURR PER FLOOR AREA 57
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 44
HEATING COST CURRENT 615
HEATING COST POTENTIAL 390
HOT WATER COST CURRENT 156
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 63
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 26, Avalon Close
LOCAL AUTHORITY LABEL Nottingham
CONSTITUENCY LABEL Nottingham North and Kimberley
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-04-01 15:26:40
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100031515432
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew