Energy Performance Certificate

South Farm, Scrayingham, YO41 1JD

EPC Report

Energy rating

Current: 86 B | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 87 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 87 Potential: 87
Field Value
LMK KEY 8802-6386-7822-2426-5803
ADDRESS1 South Farm
ADDRESS2 Scrayingham
ADDRESS3
POSTCODE YO41 1JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-08-28
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001544
COUNTY
LODGEMENT DATE 2020-09-18
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 77
ENERGY CONSUMPTION POTENTIAL 77
CO2 EMISSIONS CURRENT 1.8
CO2 EMISS CURR PER FLOOR AREA 13
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 92
LIGHTING COST POTENTIAL 92
HEATING COST CURRENT 801
HEATING COST POTENTIAL 801
HOT WATER COST CURRENT 328
HOT WATER COST POTENTIAL 328
TOTAL FLOOR AREA 136
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, plus solar
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS South Farm, Scrayingham
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Thirsk and Malton
POSTTOWN YORK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2020-09-18 13:31:29
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10000126185
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000003
Address display
Nation ew