Energy Performance Certificate

The Shippon, Park View Farm, Kentisbury, EX31 4NB

EPC Report

Energy rating

Current: 71 C | Potential: 104 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 104 A Potential: 104 A

Environmental impact (CO₂)

Current: 74 | Potential: 104
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 104 Potential: 104
Field Value
LMK KEY 8802-4795-5829-5327-3683
ADDRESS1 The Shippon
ADDRESS2 Park View Farm
ADDRESS3 Kentisbury
POSTCODE EX31 4NB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 104
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2018-06-21
LOCAL AUTHORITY E07000043
CONSTITUENCY E14001387
COUNTY
LODGEMENT DATE 2018-06-21
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 104
ENERGY CONSUMPTION CURRENT 163
ENERGY CONSUMPTION POTENTIAL -42
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 28
CO2 EMISSIONS POTENTIAL -0.7
LIGHTING COST CURRENT 69
LIGHTING COST POTENTIAL 69
HEATING COST CURRENT 391
HEATING COST POTENTIAL 391
HOT WATER COST CURRENT 347
HOT WATER COST POTENTIAL 220
TOTAL FLOOR AREA 94
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE triple glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully triple glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Flat, insulated
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Very Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.15
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Shippon, Park View Farm, Kentisbury
LOCAL AUTHORITY LABEL North Devon
CONSTITUENCY LABEL North Devon
POSTTOWN BARNSTAPLE
CONSTRUCTION AGE BAND England and Wales: 2012 onwards
LODGEMENT DATETIME 2018-06-22 00:24:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10094238865
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000009
Address display
Nation ew