Energy Performance Certificate

2, Stonehill Gate, Hancocks Mount, SL5 9WA

EPC Report

Energy rating

Current: 67 D | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 56 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 63 Potential: 63
Field Value
LMK KEY 8801-6622-5510-5876-9926
ADDRESS1 2, Stonehill Gate
ADDRESS2 Hancocks Mount
ADDRESS3
POSTCODE SL5 9WA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-02-26
LOCAL AUTHORITY E06000040
CONSTITUENCY E14001588
COUNTY
LODGEMENT DATE 2019-03-01
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 183
ENERGY CONSUMPTION POTENTIAL 153
CO2 EMISSIONS CURRENT 14.0
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 12.0
LIGHTING COST CURRENT 159
LIGHTING COST POTENTIAL 159
HEATING COST CURRENT 2342
HEATING COST POTENTIAL 2146
HOT WATER COST CURRENT 164
HOT WATER COST POTENTIAL 132
TOTAL FLOOR AREA 426
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 11
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.98
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Stonehill Gate, Hancocks Mount
LOCAL AUTHORITY LABEL Windsor and Maidenhead
CONSTITUENCY LABEL Windsor
POSTTOWN ASCOT
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2019-03-01 11:16:08
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 56
LOW ENERGY FIXED LIGHT COUNT 56
UPRN 100080346289
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew