Energy Performance Certificate

1, Norton Road, DN16 3EL

EPC Report

Energy rating

Current: 52 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 49 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 85 Potential: 85
Field Value
LMK KEY 8798-9041-3529-7497-9073
ADDRESS1 1, Norton Road
ADDRESS2
ADDRESS3
POSTCODE DN16 3EL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2013-10-14
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001462
COUNTY
LODGEMENT DATE 2013-10-14
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 367
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 55
LIGHTING COST POTENTIAL 55
HEATING COST CURRENT 599
HEATING COST POTENTIAL 394
HOT WATER COST CURRENT 196
HOT WATER COST POTENTIAL 62
TOTAL FLOOR AREA 54
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.26
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 1, Norton Road
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Scunthorpe
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-10-14 13:07:38
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100050216070
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew