Energy Performance Certificate

5, Lincoln Close, CV34 5UD

EPC Report

Energy rating

Current: 51 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 50 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 83 Potential: 83
Field Value
LMK KEY 8784-7020-2109-8933-8996
ADDRESS1 5, Lincoln Close
ADDRESS2
ADDRESS3
POSTCODE CV34 5UD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-10-17
LOCAL AUTHORITY E07000222
CONSTITUENCY E14001566
COUNTY
LODGEMENT DATE 2014-10-17
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 298
ENERGY CONSUMPTION POTENTIAL 95
CO2 EMISSIONS CURRENT 5.0
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 1.6
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 54
HEATING COST CURRENT 871
HEATING COST POTENTIAL 477
HOT WATER COST CURRENT 296
HOT WATER COST POTENTIAL 164
TOTAL FLOOR AREA 89
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.29
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Lincoln Close
LOCAL AUTHORITY LABEL Warwick
CONSTITUENCY LABEL Warwick and Leamington
POSTTOWN WARWICK
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2014-10-17 19:55:31
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100070263852
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew