Energy Performance Certificate

11, The Wharf, GU29 9PX

EPC Report

Energy rating

Current: 75 C | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 75 C Current: 75 C 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 77 | Potential: 96
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 96 Potential: 96
Field Value
LMK KEY 8778-7223-5240-8937-0992
ADDRESS1 11, The Wharf
ADDRESS2
ADDRESS3
POSTCODE GU29 9PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 75
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE Bungalow
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-07-13
LOCAL AUTHORITY E07000225
CONSTITUENCY E14001067
COUNTY
LODGEMENT DATE 2018-07-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 96
ENERGY CONSUMPTION CURRENT 176
ENERGY CONSUMPTION POTENTIAL 6
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 31
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 48
LIGHTING COST POTENTIAL 36
HEATING COST CURRENT 264
HEATING COST POTENTIAL 238
HOT WATER COST CURRENT 68
HOT WATER COST POTENTIAL 43
TOTAL FLOOR AREA 46
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, The Wharf
LOCAL AUTHORITY LABEL Chichester
CONSTITUENCY LABEL Arundel and South Downs
POSTTOWN MIDHURST
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-07-13 11:19:24
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100061763740
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew