Energy Performance Certificate

55, Albert Road, WV6 0AG

EPC Report

Energy rating

Current: 1 G | Potential: 59 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 59 D Potential: 59 D

Environmental impact (CO₂)

Current: 1 | Potential: 27
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 27 Potential: 27
Field Value
LMK KEY 8772-6022-8509-5744-1902
ADDRESS1 55, Albert Road
ADDRESS2
ADDRESS3
POSTCODE WV6 0AG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 59
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2012-12-04
LOCAL AUTHORITY E08000031
CONSTITUENCY E14001596
COUNTY
LODGEMENT DATE 2012-12-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 27
ENERGY CONSUMPTION CURRENT 726
ENERGY CONSUMPTION POTENTIAL 386
CO2 EMISSIONS CURRENT 48
CO2 EMISS CURR PER FLOOR AREA 146
CO2 EMISSIONS POTENTIAL 24
LIGHTING COST CURRENT 193
LIGHTING COST POTENTIAL 212
HEATING COST CURRENT 9442
HEATING COST POTENTIAL 2461
HOT WATER COST CURRENT 478
HOT WATER COST POTENTIAL 140
TOTAL FLOOR AREA 327
ENERGY TARIFF Unknown
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 4
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 4% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL house coal (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.9
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 55, Albert Road
LOCAL AUTHORITY LABEL Wolverhampton
CONSTITUENCY LABEL Wolverhampton West
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2012-12-09 14:35:12
TENURE Unknown
FIXED LIGHTING OUTLETS COUNT 24
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100071351549
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000005
Address display
Nation ew