Energy Performance Certificate

82a Seaside, BN22 7QP

EPC Report

Energy rating

Current: 14 G | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 14 G Current: 14 G 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 26 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 Current: 26 58 Potential: 58
Field Value
LMK KEY 8768-6723-7150-5890-7992
ADDRESS1 82a Seaside
ADDRESS2
ADDRESS3
POSTCODE BN22 7QP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 14
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE Maisonette
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-07-10
LOCAL AUTHORITY E07000061
CONSTITUENCY E14001219
COUNTY
LODGEMENT DATE 2018-07-10
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 26
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 513
ENERGY CONSUMPTION POTENTIAL 231
CO2 EMISSIONS CURRENT 9.0
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 4.1
LIGHTING COST CURRENT 72
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 2165
HEATING COST POTENTIAL 435
HOT WATER COST CURRENT 571
HOT WATER COST POTENTIAL 169
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 90
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 82a Seaside
LOCAL AUTHORITY LABEL Eastbourne
CONSTITUENCY LABEL Eastbourne
POSTTOWN EASTBOURNE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-07-10 16:34:31
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN
UPRN SOURCE
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew