Energy Performance Certificate

6, High Street, Waltham on the Wolds, LE14 4AH

EPC Report

Energy rating

Current: 11 G | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 G Current: 11 G 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 1 | Potential: 54
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 Current: 1 54 Potential: 54
Field Value
LMK KEY 8766-6920-9689-6539-8926
ADDRESS1 6, High Street
ADDRESS2 Waltham on the Wolds
ADDRESS3
POSTCODE LE14 4AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 11
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-10-21
LOCAL AUTHORITY E07000133
CONSTITUENCY E14001357
COUNTY
LODGEMENT DATE 2016-10-21
TRANSACTION TYPE RHI application
ENVIRONMENT IMPACT CURRENT 1
ENVIRONMENT IMPACT POTENTIAL 54
ENERGY CONSUMPTION CURRENT 1189
ENERGY CONSUMPTION POTENTIAL 333
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 201
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 2477
HEATING COST POTENTIAL 1053
HOT WATER COST CURRENT 222
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 79
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, High Street, Waltham on the Wolds
LOCAL AUTHORITY LABEL Melton
CONSTITUENCY LABEL Melton and Syston
POSTTOWN MELTON MOWBRAY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-10-21 16:10:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100030540461
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew