Energy Performance Certificate

8, Rowley Crescent, CV37 6UT

EPC Report

Energy rating

Current: 27 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 F Current: 27 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 21 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 Current: 21 66 Potential: 66
Field Value
LMK KEY 8766-6722-5100-8708-2992
ADDRESS1 8, Rowley Crescent
ADDRESS2
ADDRESS3
POSTCODE CV37 6UT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 27
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-02-18
LOCAL AUTHORITY E07000221
CONSTITUENCY E14001526
COUNTY
LODGEMENT DATE 2016-02-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 21
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 460
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 27
CO2 EMISS CURR PER FLOOR AREA 84
CO2 EMISSIONS POTENTIAL 8.6
LIGHTING COST CURRENT 149
LIGHTING COST POTENTIAL 149
HEATING COST CURRENT 5214
HEATING COST POTENTIAL 1822
HOT WATER COST CURRENT 190
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 321
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 85
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 9
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 78
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, plus solar, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly secondary glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 78% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.87
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG Y
MECHANICAL VENTILATION natural
ADDRESS 8, Rowley Crescent
LOCAL AUTHORITY LABEL Stratford-on-Avon
CONSTITUENCY LABEL Stratford-on-Avon
POSTTOWN STRATFORD-UPON-AVON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-02-19 15:12:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 100070222303
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew