Energy Performance Certificate

25, Hylands Road, E17 4AJ

EPC Report

Energy rating

Current: 34 F | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 46 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 74 Potential: 74
Field Value
LMK KEY 8765-7821-3350-4883-6902
ADDRESS1 25, Hylands Road
ADDRESS2
ADDRESS3
POSTCODE E17 4AJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-09-07
LOCAL AUTHORITY E09000031
CONSTITUENCY E14001563
COUNTY
LODGEMENT DATE 2015-09-08
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 476
ENERGY CONSUMPTION POTENTIAL 215
CO2 EMISSIONS CURRENT 3.0
CO2 EMISS CURR PER FLOOR AREA 81
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 40
LIGHTING COST POTENTIAL 40
HEATING COST CURRENT 708
HEATING COST POTENTIAL 262
HOT WATER COST CURRENT 218
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 38
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 67
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 67% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 4.75
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25, Hylands Road
LOCAL AUTHORITY LABEL Waltham Forest
CONSTITUENCY LABEL Walthamstow
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-09-08 01:53:53
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100022557542
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000007
Address display
Nation ew