Energy Performance Certificate

40, Dean Street, FY4 1BP

EPC Report

Energy rating

Current: 31 F | Potential: 76 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 76 C Potential: 76 C

Environmental impact (CO₂)

Current: 27 | Potential: 72
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 27 Current: 27 72 Potential: 72
Field Value
LMK KEY 8755-7220-4999-4020-4972
ADDRESS1 40, Dean Street
ADDRESS2
ADDRESS3
POSTCODE FY4 1BP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 76
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-10-30
LOCAL AUTHORITY E06000009
CONSTITUENCY E14001105
COUNTY
LODGEMENT DATE 2015-11-02
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 27
ENVIRONMENT IMPACT POTENTIAL 72
ENERGY CONSUMPTION CURRENT 435
ENERGY CONSUMPTION POTENTIAL 143
CO2 EMISSIONS CURRENT 19
CO2 EMISS CURR PER FLOOR AREA 76
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 132
LIGHTING COST POTENTIAL 132
HEATING COST CURRENT 3836
HEATING COST POTENTIAL 1430
HOT WATER COST CURRENT 227
HOT WATER COST POTENTIAL 117
TOTAL FLOOR AREA 249
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 68
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 68% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Dean Street
LOCAL AUTHORITY LABEL Blackpool
CONSTITUENCY LABEL Blackpool South
POSTTOWN BLACKPOOL
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-11-02 08:34:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10090937661
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew