Energy Performance Certificate

Knab Hall, Knabb Road, Two Dales, DE4 2FJ

EPC Report

Energy rating

Current: 34 F | Potential: 61 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 F Current: 34 F 61 D Potential: 61 D

Environmental impact (CO₂)

Current: 29 | Potential: 50
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 50 Potential: 50
Field Value
LMK KEY 8747-7929-1809-2599-4926
ADDRESS1 Knab Hall
ADDRESS2 Knabb Road
ADDRESS3 Two Dales
POSTCODE DE4 2FJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 34
POTENTIAL ENERGY EFFICIENCY 61
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-11-21
LOCAL AUTHORITY E07000035
CONSTITUENCY E14001195
COUNTY
LODGEMENT DATE 2013-11-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 50
ENERGY CONSUMPTION CURRENT 288
ENERGY CONSUMPTION POTENTIAL 166
CO2 EMISSIONS CURRENT 29
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 17
LIGHTING COST CURRENT 251
LIGHTING COST POTENTIAL 127
HEATING COST CURRENT 5918
HEATING COST POTENTIAL 3622
HOT WATER COST CURRENT 191
HOT WATER COST POTENTIAL 191
TOTAL FLOOR AREA 423
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 55
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 14
NUMBER HEATED ROOMS 9
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.99
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Knab Hall, Knabb Road, Two Dales
LOCAL AUTHORITY LABEL Derbyshire Dales
CONSTITUENCY LABEL Derbyshire Dales
POSTTOWN MATLOCK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-11-21 17:10:58
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10070097908
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000004
Address display