Energy Performance Certificate

91, Palmer Road, BB1 8BS

EPC Report

Energy rating

Current: 13 G | Potential: 67 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 G Current: 13 G 67 D Potential: 67 D

Environmental impact (CO₂)

Current: 15 | Potential: 61
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 Current: 15 61 Potential: 61
Field Value
LMK KEY 8747-7629-0819-2845-2922
ADDRESS1 91, Palmer Road
ADDRESS2
ADDRESS3
POSTCODE BB1 8BS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 13
POTENTIAL ENERGY EFFICIENCY 67
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2013-11-25
LOCAL AUTHORITY E06000008
CONSTITUENCY E14001102
COUNTY
LODGEMENT DATE 2013-11-25
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 15
ENVIRONMENT IMPACT POTENTIAL 61
ENERGY CONSUMPTION CURRENT 609
ENERGY CONSUMPTION POTENTIAL 197
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 116
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 121
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 2322
HEATING COST POTENTIAL 1012
HOT WATER COST CURRENT 487
HOT WATER COST POTENTIAL 97
TOTAL FLOOR AREA 123
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 95
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 8
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 8% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 91, Palmer Road
LOCAL AUTHORITY LABEL Blackburn with Darwen
CONSTITUENCY LABEL Blackburn
POSTTOWN BLACKBURN
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-11-25 15:20:12
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100010752617
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew