Energy Performance Certificate

16a, Southfield, BA3 3NU

EPC Report

Energy rating

Current: 57 D | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 34 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 34 Current: 34 62 Potential: 62
Field Value
LMK KEY 8746-7322-4210-9284-1902
ADDRESS1 16a, Southfield
ADDRESS2
ADDRESS3
POSTCODE BA3 3NU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-02-04
LOCAL AUTHORITY E06000022
CONSTITUENCY E14001241
COUNTY
LODGEMENT DATE 2016-02-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 34
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 569
ENERGY CONSUMPTION POTENTIAL 298
CO2 EMISSIONS CURRENT 5.1
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 569
HEATING COST POTENTIAL 241
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 143
TOTAL FLOOR AREA 52
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 1
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH 0
FLOOR HEIGHT 2.56
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16a, Southfield
LOCAL AUTHORITY LABEL Bath and North East Somerset
CONSTITUENCY LABEL Frome and East Somerset
POSTTOWN RADSTOCK
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-02-04 20:01:03
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 10001126388
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000009
Address display
Nation ew