Energy Performance Certificate

17, Bothal Street, NE6 2JQ

EPC Report

Energy rating

Current: 58 D | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 50 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 79 Potential: 79
Field Value
LMK KEY 8745-6129-9619-7342-6992
ADDRESS1 17, Bothal Street
ADDRESS2
ADDRESS3
POSTCODE NE6 2JQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-11-12
LOCAL AUTHORITY E08000021
CONSTITUENCY E14001378
COUNTY
LODGEMENT DATE 2015-11-13
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 286
ENERGY CONSUMPTION POTENTIAL 117
CO2 EMISSIONS CURRENT 6.3
CO2 EMISS CURR PER FLOOR AREA 50
CO2 EMISSIONS POTENTIAL 2.6
LIGHTING COST CURRENT 128
LIGHTING COST POTENTIAL 71
HEATING COST CURRENT 1137
HEATING COST POTENTIAL 668
HOT WATER COST CURRENT 121
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 124
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 18
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 18% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.91
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17, Bothal Street
LOCAL AUTHORITY LABEL Newcastle upon Tyne
CONSTITUENCY LABEL Newcastle upon Tyne East and Wallsend
POSTTOWN NEWCASTLE UPON TYNE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-11-13 08:08:34
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 4510066990
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000001
Address display
Nation ew