Energy Performance Certificate

Flat 1 Collingwood House, 103, New Cavendish Street, W1W 6XH

EPC Report

Energy rating

Current: 73 C | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 C Current: 73 C 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 71 | Potential: 71
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 Current: 71 71 Potential: 71
Field Value
LMK KEY 8738-6822-6919-9611-0996
ADDRESS1 Flat 1 Collingwood House
ADDRESS2 103, New Cavendish Street
ADDRESS3
POSTCODE W1W 6XH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 73
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-12-19
LOCAL AUTHORITY E09000033
CONSTITUENCY E14001172
COUNTY
LODGEMENT DATE 2018-12-27
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 71
ENVIRONMENT IMPACT POTENTIAL 71
ENERGY CONSUMPTION CURRENT 231
ENERGY CONSUMPTION POTENTIAL 231
CO2 EMISSIONS CURRENT 2.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 41
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 327
HEATING COST POTENTIAL 327
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 105
TOTAL FLOOR AREA 52
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Flat rate charging, no thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Community scheme
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Full secondary glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION (another dwelling above)
ROOF ENERGY EFF N/A
ROOF ENV EFF N/A
MAINHEAT DESCRIPTION Community scheme
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Flat rate charging, no thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.444
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Flat 1 Collingwood House, 103, New Cavendish Street
LOCAL AUTHORITY LABEL Westminster
CONSTITUENCY LABEL Cities of London and Westminster
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2018-12-27 11:32:34
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10033605182
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000007
Address display
Nation ew