Energy Performance Certificate

129, Gibraltar Road, HX1 3UH

EPC Report

Energy rating

Current: 56 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 48 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 79 Potential: 79
Field Value
LMK KEY 8736-6625-7680-5010-2996
ADDRESS1 129, Gibraltar Road
ADDRESS2
ADDRESS3
POSTCODE HX1 3UH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-05-10
LOCAL AUTHORITY E08000033
CONSTITUENCY E14001262
COUNTY
LODGEMENT DATE 2016-05-11
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 355
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1097
HEATING COST POTENTIAL 652
HOT WATER COST CURRENT 111
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 93
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 129, Gibraltar Road
LOCAL AUTHORITY LABEL Calderdale
CONSTITUENCY LABEL Halifax
POSTTOWN HALIFAX
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-05-11 09:36:17
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100051320192
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew