Energy Performance Certificate

27 Curre Street, CF44 6UF

EPC Report

Energy rating

Current: 47 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 47 E Current: 47 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 40 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 75 Potential: 75
Field Value
LMK KEY 8735-7328-9500-0764-3202
ADDRESS1 27 Curre Street
ADDRESS2
ADDRESS3
POSTCODE CF44 6UF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 47
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-08-04
LOCAL AUTHORITY W06000016
CONSTITUENCY W07000099
COUNTY
LODGEMENT DATE 2025-08-05
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 371
ENERGY CONSUMPTION POTENTIAL 138
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 101
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 1860
HEATING COST POTENTIAL 853
HOT WATER COST CURRENT 630
HOT WATER COST POTENTIAL 222
TOTAL FLOOR AREA 111
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.77
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27 Curre Street
LOCAL AUTHORITY LABEL Rhondda Cynon Taf
CONSTITUENCY LABEL Merthyr Tydfil and Aberdare
POSTTOWN ABERDARE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2025-08-05 11:13:44
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100100705603
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY Wales
REGION W99999999
Address display