Energy Performance Certificate

57, Buller Close, TN6 2YE

EPC Report

Energy rating

Current: 57 D | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 37 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 74 Potential: 74
Field Value
LMK KEY 8731-6727-5940-1024-1906
ADDRESS1 57, Buller Close
ADDRESS2
ADDRESS3
POSTCODE TN6 2YE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-03-04
LOCAL AUTHORITY E07000065
CONSTITUENCY E14001533
COUNTY
LODGEMENT DATE 2019-03-04
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 594
ENERGY CONSUMPTION POTENTIAL 201
CO2 EMISSIONS CURRENT 4.4
CO2 EMISS CURR PER FLOOR AREA 100
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 45
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 639
HEATING COST POTENTIAL 342
HOT WATER COST CURRENT 165
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 44
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 15
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 57, Buller Close
LOCAL AUTHORITY LABEL Wealden
CONSTITUENCY LABEL Sussex Weald
POSTTOWN CROWBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2019-03-04 12:51:59
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100060106337
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew