Energy Performance Certificate

2, Atwick Road, Bewholme, YO25 8DT

EPC Report

Energy rating

Current: 51 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 40 | Potential: 75
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 75 Potential: 75
Field Value
LMK KEY 8722-6925-9890-2768-8902
ADDRESS1 2, Atwick Road
ADDRESS2 Bewholme
ADDRESS3
POSTCODE YO25 8DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-05-08
LOCAL AUTHORITY E06000011
CONSTITUENCY E14001127
COUNTY
LODGEMENT DATE 2012-05-10
TRANSACTION TYPE marketed sale
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 75
ENERGY CONSUMPTION CURRENT 275
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 113
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 1094
HEATING COST POTENTIAL 596
HOT WATER COST CURRENT 135
HOT WATER COST POTENTIAL 89
TOTAL FLOOR AREA 113
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.52
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Atwick Road, Bewholme
LOCAL AUTHORITY LABEL East Riding of Yorkshire
CONSTITUENCY LABEL Bridlington and The Wolds
POSTTOWN DRIFFIELD
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2012-05-10 23:13:40
TENURE
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100050046248
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2012.csv
COUNTRY England
REGION E12000003
Address display
Nation ew