Energy Performance Certificate

6, Ridyard Street, Little Hulton, M38 9LN

EPC Report

Energy rating

Current: 44 E | Potential: 84 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 44 E Current: 44 E 84 B Potential: 84 B

Environmental impact (CO₂)

Current: 29 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 84 Potential: 84
Field Value
LMK KEY 8717-7425-0200-4875-8992
ADDRESS1 6, Ridyard Street
ADDRESS2 Little Hulton
ADDRESS3
POSTCODE M38 9LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 44
POTENTIAL ENERGY EFFICIENCY 84
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-05-15
LOCAL AUTHORITY E08000006
CONSTITUENCY E14001111
COUNTY
LODGEMENT DATE 2013-05-15
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 536
ENERGY CONSUMPTION POTENTIAL 90
CO2 EMISSIONS CURRENT 7.6
CO2 EMISS CURR PER FLOOR AREA 95
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 100
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 828
HEATING COST POTENTIAL 436
HOT WATER COST CURRENT 286
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 80
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Automatic charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Automatic charge control
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.36
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Ridyard Street, Little Hulton
LOCAL AUTHORITY LABEL Salford
CONSTITUENCY LABEL Bolton South and Walkden
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2013-05-15 20:14:44
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100011384944
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000002
Address display
Nation ew