Energy Performance Certificate

27, Campbell Grove, DN37 9AH

EPC Report

Energy rating

Current: 41 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 E Current: 41 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 50 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 50 Current: 50 78 Potential: 78
Field Value
LMK KEY 8716-7529-0099-0059-5992
ADDRESS1 27, Campbell Grove
ADDRESS2
ADDRESS3
POSTCODE DN37 9AH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 41
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-11-11
LOCAL AUTHORITY E06000012
CONSTITUENCY E14001255
COUNTY
LODGEMENT DATE 2016-11-13
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 50
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 331
ENERGY CONSUMPTION POTENTIAL 131
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 2.0
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1637
HEATING COST POTENTIAL 604
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 80
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 80% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.3
PHOTO SUPPLY 50
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 27, Campbell Grove
LOCAL AUTHORITY LABEL North East Lincolnshire
CONSTITUENCY LABEL Great Grimsby and Cleethorpes
POSTTOWN GRIMSBY
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2016-11-13 13:58:22
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10