Energy Performance Certificate

37, Hawker Square, Upper Rissington, GL54 2NT

EPC Report

Energy rating

Current: 59 D | Potential: 100 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 100 A Potential: 100 A

Environmental impact (CO₂)

Current: 74 | Potential: 106
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 Current: 74 106 Potential: 106
Field Value
LMK KEY 8715-7822-3410-9297-2902
ADDRESS1 37, Hawker Square
ADDRESS2 Upper Rissington
ADDRESS3
POSTCODE GL54 2NT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 100
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-02-03
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001386
COUNTY
LODGEMENT DATE 2015-02-03
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 74
ENVIRONMENT IMPACT POTENTIAL 106
ENERGY CONSUMPTION CURRENT 226
ENERGY CONSUMPTION POTENTIAL -12
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 27
CO2 EMISSIONS POTENTIAL -0.8
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 795
HEATING COST POTENTIAL 622
HOT WATER COST CURRENT 248
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 105
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 59
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, LPG, Boiler and radiators, wood logs
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 59% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL LPG special condition
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 37, Hawker Square, Upper Rissington
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL North Cotswolds
POSTTOWN CHELTENHAM
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-02-03 21:03:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 17
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100120415538
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv