Energy Performance Certificate

24, Harcourt Drive, CT2 8DP

EPC Report

Energy rating

Current: 35 F | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 32 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 83 Potential: 83
Field Value
LMK KEY 8713-7729-4180-5923-3926
ADDRESS1 24, Harcourt Drive
ADDRESS2
ADDRESS3
POSTCODE CT2 8DP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2017-01-27
LOCAL AUTHORITY E07000106
CONSTITUENCY E14001151
COUNTY
LODGEMENT DATE 2017-01-29
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 486
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 6.0
CO2 EMISS CURR PER FLOOR AREA 85
CO2 EMISSIONS POTENTIAL 1.1
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 49
HEATING COST CURRENT 1169
HEATING COST POTENTIAL 447
HOT WATER COST CURRENT 94
HOT WATER COST POTENTIAL 52
TOTAL FLOOR AREA 71
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 55
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 24, Harcourt Drive
LOCAL AUTHORITY LABEL Canterbury
CONSTITUENCY LABEL Canterbury
POSTTOWN CANTERBURY
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-01-29 09:58:11
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100060813844
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000008
Address display
Nation ew