Energy Performance Certificate

14, Highland Crescent, Dyffryn Cellwen, SA10 9LE

EPC Report

Energy rating

Current: 19 G | Potential: 62 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 19 G Current: 19 G 62 D Potential: 62 D

Environmental impact (CO₂)

Current: 18 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 52 Potential: 52
Field Value
LMK KEY 8713-6929-7740-8330-5922
ADDRESS1 14, Highland Crescent
ADDRESS2 Dyffryn Cellwen
ADDRESS3
POSTCODE SA10 9LE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 19
POTENTIAL ENERGY EFFICIENCY 62
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-01-20
LOCAL AUTHORITY W06000012
CONSTITUENCY W07000103
COUNTY
LODGEMENT DATE 2017-01-20
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 418
ENERGY CONSUMPTION POTENTIAL 157
CO2 EMISSIONS CURRENT 11
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 4.7
LIGHTING COST CURRENT 129
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 1367
HEATING COST POTENTIAL 635
HOT WATER COST CURRENT 137
HOT WATER COST POTENTIAL 143
TOTAL FLOOR AREA 101
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Highland Crescent, Dyffryn Cellwen
LOCAL AUTHORITY LABEL Neath Port Talbot
CONSTITUENCY LABEL Neath and Swansea East
POSTTOWN NEATH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2017-01-20 12:55:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100616691
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew