Energy Performance Certificate

19b, Station Road, Ramsey, PE26 1JB

EPC Report

Energy rating

Current: 72 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 C Current: 72 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 73 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 73 Current: 73 90 Potential: 90
Field Value
LMK KEY 8709-4635-1629-5296-2913
ADDRESS1 19b, Station Road
ADDRESS2 Ramsey
ADDRESS3
POSTCODE PE26 1JB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 72
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Enclosed End-Terrace
INSPECTION DATE 2019-01-17
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001401
COUNTY
LODGEMENT DATE 2019-01-17
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 73
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 203
ENERGY CONSUMPTION POTENTIAL 57
CO2 EMISSIONS CURRENT 1.9
CO2 EMISS CURR PER FLOOR AREA 36
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 309
HEATING COST POTENTIAL 289
HOT WATER COST CURRENT 111
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 71
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 71% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19b, Station Road, Ramsey
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL North West Cambridgeshire
POSTTOWN HUNTINGDON
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2019-01-17 11:25:13
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100090119058
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew