Energy Performance Certificate

13, Saxon Crescent, DN35 8EF

EPC Report

Energy rating

Current: 39 E | Potential: 72 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 72 C Potential: 72 C

Environmental impact (CO₂)

Current: 28 | Potential: 58
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 58 Potential: 58
Field Value
LMK KEY 8708-4034-0229-8527-3963
ADDRESS1 13, Saxon Crescent
ADDRESS2
ADDRESS3
POSTCODE DN35 8EF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 72
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-01-27
LOCAL AUTHORITY E06000012
CONSTITUENCY E14001255
COUNTY
LODGEMENT DATE 2016-02-05
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 58
ENERGY CONSUMPTION CURRENT 473
ENERGY CONSUMPTION POTENTIAL 207
CO2 EMISSIONS CURRENT 8.9
CO2 EMISS CURR PER FLOOR AREA 97
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 108
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1480
HEATING COST POTENTIAL 875
HOT WATER COST CURRENT 107
HOT WATER COST POTENTIAL 81
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 36
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.49
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 13, Saxon Crescent
LOCAL AUTHORITY LABEL North East Lincolnshire
CONSTITUENCY LABEL Great Grimsby and Cleethorpes
POSTTOWN CLEETHORPES
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-02-05 17:03:15
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 21
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 11003022
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew