Energy Performance Certificate

16, Cecil Avenue, BS5 7SD

EPC Report

Energy rating

Current: 39 E | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 E Current: 39 E 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 37 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 91 Potential: 91
Field Value
LMK KEY 8707-7341-3329-9007-9173
ADDRESS1 16, Cecil Avenue
ADDRESS2
ADDRESS3
POSTCODE BS5 7SD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 39
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2013-09-04
LOCAL AUTHORITY E06000023
CONSTITUENCY E14001132
COUNTY
LODGEMENT DATE 2013-09-04
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 459
ENERGY CONSUMPTION POTENTIAL 42
CO2 EMISSIONS CURRENT 4.9
CO2 EMISS CURR PER FLOOR AREA 88
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 702
HEATING COST POTENTIAL 318
HOT WATER COST CURRENT 273
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 55
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 85
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 17
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 17% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Cecil Avenue
LOCAL AUTHORITY LABEL Bristol, City of
CONSTITUENCY LABEL Bristol East
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2013-09-04 11:41:35
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 77335
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew