Energy Performance Certificate

5, Sunhurst Drive, Oakworth, BD22 7RG

EPC Report

Energy rating

Current: 57 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 D Current: 57 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 35 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 Current: 35 90 Potential: 90
Field Value
LMK KEY 8707-4104-5329-6597-4763
ADDRESS1 5, Sunhurst Drive
ADDRESS2 Oakworth
ADDRESS3
POSTCODE BD22 7RG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 57
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2016-03-10
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001308
COUNTY
LODGEMENT DATE 2016-03-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 35
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 651
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 6.1
CO2 EMISS CURR PER FLOOR AREA 110
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 50
LIGHTING COST POTENTIAL 45
HEATING COST CURRENT 627
HEATING COST POTENTIAL 382
HOT WATER COST CURRENT 300
HOT WATER COST POTENTIAL 59
TOTAL FLOOR AREA 55
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 83
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 83% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Sunhurst Drive, Oakworth
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Keighley and Ilkley
POSTTOWN KEIGHLEY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2016-03-10 10:22:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 6
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100051274123
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew