Energy Performance Certificate

11, Ribble Crescent, Billinge, WN5 7QX

EPC Report

Energy rating

Current: 42 E | Potential: 63 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 E Current: 42 E 63 D Potential: 63 D

Environmental impact (CO₂)

Current: 40 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 Current: 40 59 Potential: 59
Field Value
LMK KEY 8704-0392-8529-4797-3343
ADDRESS1 11, Ribble Crescent
ADDRESS2 Billinge
ADDRESS3
POSTCODE WN5 7QX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 42
POTENTIAL ENERGY EFFICIENCY 63
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2014-07-11
LOCAL AUTHORITY E08000013
CONSTITUENCY E14001509
COUNTY
LODGEMENT DATE 2014-07-15
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 40
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 346
ENERGY CONSUMPTION POTENTIAL 217
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 83
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 1524
HEATING COST POTENTIAL 1197
HOT WATER COST CURRENT 122
HOT WATER COST POTENTIAL 76
TOTAL FLOOR AREA 112
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 70
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 70% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Ribble Crescent, Billinge
LOCAL AUTHORITY LABEL St. Helens
CONSTITUENCY LABEL St Helens North
POSTTOWN WIGAN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-07-15 11:36:58
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 39050090
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew