Energy Performance Certificate

16, Maes y Glyn, Lower Brynamman, SA18 1SY

EPC Report

Energy rating

Current: 74 C | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 74 C Current: 74 C 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 68 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 68 Current: 68 69 Potential: 69
Field Value
LMK KEY 8703-2508-5922-2976-5703
ADDRESS1 16, Maes y Glyn
ADDRESS2 Lower Brynamman
ADDRESS3
POSTCODE SA18 1SY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 74
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2020-03-30
LOCAL AUTHORITY W06000012
CONSTITUENCY W07000085
COUNTY
LODGEMENT DATE 2020-06-11
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 68
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 159
ENERGY CONSUMPTION POTENTIAL 155
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 50
HEATING COST CURRENT 171
HEATING COST POTENTIAL 173
HOT WATER COST CURRENT 185
HOT WATER COST POTENTIAL 185
TOTAL FLOOR AREA 59
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 2
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double, known data
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 66
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 66% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Maes y Glyn, Lower Brynamman
LOCAL AUTHORITY LABEL Neath Port Talbot
CONSTITUENCY LABEL Brecon, Radnor and Cwm Tawe
POSTTOWN AMMANFORD
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-06-11 13:34:24
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 100
LOW ENERGY FIXED LIGHT COUNT 66
UPRN 100100621009
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew