Energy Performance Certificate

North View, North Road, SY22 6EA

EPC Report

Energy rating

Current: 40 E | Potential: 51 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 51 E Potential: 51 E

Environmental impact (CO₂)

Current: 57 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 57 Current: 57 66 Potential: 66
Field Value
LMK KEY 8703-2083-0429-4827-1663
ADDRESS1 North View
ADDRESS2 North Road
ADDRESS3
POSTCODE SY22 6EA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 51
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-06-28
LOCAL AUTHORITY E06000051
CONSTITUENCY E14001398
COUNTY
LODGEMENT DATE 2016-07-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 57
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 175
ENERGY CONSUMPTION POTENTIAL 127
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 43
CO2 EMISSIONS POTENTIAL 4.4
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 1487
HEATING COST POTENTIAL 1487
HOT WATER COST CURRENT 244
HOT WATER COST POTENTIAL 153
TOTAL FLOOR AREA 128
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, with internal insulation
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, coal
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL bottled LPG
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS North View, North Road
LOCAL AUTHORITY LABEL Shropshire
CONSTITUENCY LABEL North Shropshire
POSTTOWN LLANYMYNECH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2016-07-28 12:08:53
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 14
UPRN 10011768814
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION E12000005
Address display
Nation ew