Energy Performance Certificate

5, Recreation View, LS11 0AP

EPC Report

Energy rating

Current: 11 G | Potential: 92 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 11 G Current: 11 G 92 A Potential: 92 A

Environmental impact (CO₂)

Current: 24 | Potential: 93
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 24 Current: 24 93 Potential: 93
Field Value
LMK KEY 8702-7494-2829-5827-8633
ADDRESS1 5, Recreation View
ADDRESS2
ADDRESS3
POSTCODE LS11 0AP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 11
POTENTIAL ENERGY EFFICIENCY 92
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2017-06-21
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001323
COUNTY
LODGEMENT DATE 2017-07-17
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 24
ENVIRONMENT IMPACT POTENTIAL 93
ENERGY CONSUMPTION CURRENT 785
ENERGY CONSUMPTION POTENTIAL 52
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 133
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 37
HEATING COST CURRENT 1484
HEATING COST POTENTIAL 281
HOT WATER COST CURRENT 490
HOT WATER COST POTENTIAL 54
TOTAL FLOOR AREA 51
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION To unheated space, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 5, Recreation View
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds South
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-07-17 14:01:40
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 72167550
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000003
Address display
Nation ew