Energy Performance Certificate

47, Northcote Avenue, Wythenshawe, M22 9AJ

EPC Report

Energy rating

Current: 70 C | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 65 | Potential: 80
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 80 Potential: 80
Field Value
LMK KEY 8701-9516-6629-6607-6113
ADDRESS1 47, Northcote Avenue
ADDRESS2 Wythenshawe
ADDRESS3
POSTCODE M22 9AJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2019-09-09
LOCAL AUTHORITY E08000003
CONSTITUENCY E14001602
COUNTY
LODGEMENT DATE 2019-09-09
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 80
ENERGY CONSUMPTION CURRENT 194
ENERGY CONSUMPTION POTENTIAL 109
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 642
HEATING COST POTENTIAL 559
HOT WATER COST CURRENT 131
HOT WATER COST POTENTIAL 77
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 58
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 58% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 47, Northcote Avenue, Wythenshawe
LOCAL AUTHORITY LABEL Manchester
CONSTITUENCY LABEL Wythenshawe and Sale East
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 2003-2006
LODGEMENT DATETIME 2019-09-09 18:48:04
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 7
UPRN 10070391743
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000002
Address display
Nation ew