Energy Performance Certificate

11, Forester Road, BA2 6QF

EPC Report

Energy rating

Current: 52 E | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 E Current: 52 E 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 45 | Potential: 64
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 64 Potential: 64
Field Value
LMK KEY 8701-2330-0429-5997-2973
ADDRESS1 11, Forester Road
ADDRESS2
ADDRESS3
POSTCODE BA2 6QF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 52
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-01-17
LOCAL AUTHORITY E06000022
CONSTITUENCY E14001080
COUNTY
LODGEMENT DATE 2013-01-18
TRANSACTION TYPE Non-marketed sale
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 64
ENERGY CONSUMPTION CURRENT 254
ENERGY CONSUMPTION POTENTIAL 151
CO2 EMISSIONS CURRENT 9.6
CO2 EMISS CURR PER FLOOR AREA 49
CO2 EMISSIONS POTENTIAL 5.8
LIGHTING COST CURRENT 123
LIGHTING COST POTENTIAL 80
HEATING COST CURRENT 1601
HEATING COST POTENTIAL 1177
HOT WATER COST CURRENT 127
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 195
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 91
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.07
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Forester Road
LOCAL AUTHORITY LABEL Bath and North East Somerset
CONSTITUENCY LABEL Bath
POSTTOWN BATH
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-01-18 11:47:03
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100120010448
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew