Energy Performance Certificate

76a, Trinity Square, CT9 1HS

EPC Report

Energy rating

Current: 40 E | Potential: 97 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 40 E Current: 40 E 97 A Potential: 97 A

Environmental impact (CO₂)

Current: 28 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 28 Current: 28 85 Potential: 85
Field Value
LMK KEY 8700-1015-9529-5226-2813
ADDRESS1 76a, Trinity Square
ADDRESS2
ADDRESS3
POSTCODE CT9 1HS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 40
POTENTIAL ENERGY EFFICIENCY 97
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-08-29
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001216
COUNTY
LODGEMENT DATE 2019-09-09
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 28
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 913
ENERGY CONSUMPTION POTENTIAL 105
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 154
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 28
HEATING COST CURRENT 736
HEATING COST POTENTIAL 242
HOT WATER COST CURRENT 168
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 28
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 85
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.21
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 76a, Trinity Square
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL East Thanet
POSTTOWN MARGATE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-09-09 11:51:05
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 100061129628
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000008
Address display
Nation ew