Energy Performance Certificate
117, London Road, New Balderton, NG24 3AA
Energy rating
Current: 56 D | Potential: 72 C
Environmental impact (CO₂)
Current: 49
| Potential: 64
| Field | Value |
|---|---|
| LMK KEY | 8698-6529-7359-7347-9926 |
| ADDRESS1 | 117, London Road |
| ADDRESS2 | New Balderton |
| ADDRESS3 | — |
| POSTCODE | NG24 3AA |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | C |
| CURRENT ENERGY EFFICIENCY | 56 |
| POTENTIAL ENERGY EFFICIENCY | 72 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2018-11-23 |
| LOCAL AUTHORITY | E07000175 |
| CONSTITUENCY | E14001375 |
| COUNTY | — |
| LODGEMENT DATE | 2018-11-24 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 49 |
| ENVIRONMENT IMPACT POTENTIAL | 64 |
| ENERGY CONSUMPTION CURRENT | 340 |
| ENERGY CONSUMPTION POTENTIAL | 229 |
| CO2 EMISSIONS CURRENT | 4.5 |
| CO2 EMISS CURR PER FLOOR AREA | 60 |
| CO2 EMISSIONS POTENTIAL | 3.1 |
| LIGHTING COST CURRENT | 106 |
| LIGHTING COST POTENTIAL | 61 |
| HEATING COST CURRENT | 776 |
| HEATING COST POTENTIAL | 740 |
| HOT WATER COST CURRENT | 99 |
| HOT WATER COST POTENTIAL | 71 |
| TOTAL FLOOR AREA | 76 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, room thermostat and TRVs |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 2 |
| NUMBER HABITABLE ROOMS | 4 |
| NUMBER HEATED ROOMS | 4 |
| LOW ENERGY LIGHTING | 25 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | Room heaters, mains gas |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, no insulation (assumed) |
| ROOF ENERGY EFF | Very Poor |
| ROOF ENV EFF | Very Poor |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, room thermostat and TRVs |
| MAINHEATC ENERGY EFF | Good |
| MAINHEATC ENV EFF | Good |
| LIGHTING DESCRIPTION | Low energy lighting in 25% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.28 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 117, London Road, New Balderton |
| LOCAL AUTHORITY LABEL | Newark and Sherwood |
| CONSTITUENCY LABEL | Newark |
| POSTTOWN | NEWARK |
| CONSTRUCTION AGE BAND | England and Wales: before 1900 |
| LODGEMENT DATETIME | 2018-11-24 10:15:37 |
| TENURE | rented (private) |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| UPRN | 100031449067 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2018.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |