Energy Performance Certificate

4, The Green, Brynna, CF72 9ZR

EPC Report

Energy rating

Current: 77 C | Potential: 77 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 C Current: 77 C 77 C Potential: 77 C

Environmental impact (CO₂)

Current: 77 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 77 Potential: 77
Field Value
LMK KEY 8697-7735-0110-3819-4926
ADDRESS1 4, The Green
ADDRESS2 Brynna
ADDRESS3
POSTCODE CF72 9ZR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 77
POTENTIAL ENERGY EFFICIENCY 77
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-05-21
LOCAL AUTHORITY W06000016
CONSTITUENCY W07000106
COUNTY
LODGEMENT DATE 2013-05-21
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 121
ENERGY CONSUMPTION POTENTIAL 121
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 21
CO2 EMISSIONS POTENTIAL 3.8
LIGHTING COST CURRENT 73
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 708
HEATING COST POTENTIAL 708
HOT WATER COST CURRENT 111
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 178
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.16 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.13 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.52
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 4, The Green, Brynna
LOCAL AUTHORITY LABEL Rhondda Cynon Taf
CONSTITUENCY LABEL Pontypridd
POSTTOWN PONTYCLUN
CONSTRUCTION AGE BAND 2013
LODGEMENT DATETIME 2013-05-21 16:54:02
TENURE
FIXED LIGHTING OUTLETS COUNT 51
LOW ENERGY FIXED LIGHT COUNT 51
UPRN 10090841375
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew