Energy Performance Certificate

Briarwood, Kent Avenue, Theddlethorpe, LN12 1QE

EPC Report

Energy rating

Current: 1 G | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 12 | Potential: 94
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 12 Current: 12 94 Potential: 94
Field Value
LMK KEY 8694-8454-0029-1827-4063
ADDRESS1 Briarwood
ADDRESS2 Kent Avenue
ADDRESS3 Theddlethorpe
POSTCODE LN12 1QE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2016-10-25
LOCAL AUTHORITY E07000137
CONSTITUENCY E14001343
COUNTY
LODGEMENT DATE 2016-10-25
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 12
ENVIRONMENT IMPACT POTENTIAL 94
ENERGY CONSUMPTION CURRENT 615
ENERGY CONSUMPTION POTENTIAL -9
CO2 EMISSIONS CURRENT 14
CO2 EMISS CURR PER FLOOR AREA 135
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 112
LIGHTING COST POTENTIAL 73
HEATING COST CURRENT 3514
HEATING COST POTENTIAL 970
HOT WATER COST CURRENT 1004
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 107
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 10
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 45
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, LPG
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 45% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL LPG (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.74
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Briarwood, Kent Avenue, Theddlethorpe
LOCAL AUTHORITY LABEL East Lindsey
CONSTITUENCY LABEL Louth and Horncastle
POSTTOWN MABLETHORPE
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-10-25 22:35:58
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10008519101
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000004
Address display
Nation ew