Energy Performance Certificate

St. Marys House, 47, High Street, Trumpington, CB2 9HZ

EPC Report

Energy rating

Current: 56 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 D Current: 56 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 55 | Potential: 70
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 70 Potential: 70
Field Value
LMK KEY 8693-6006-5229-9827-2283
ADDRESS1 St. Marys House
ADDRESS2 47, High Street
ADDRESS3 Trumpington
POSTCODE CB2 9HZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 56
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2018-12-20
LOCAL AUTHORITY E07000008
CONSTITUENCY E14001149
COUNTY
LODGEMENT DATE 2018-12-21
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 70
ENERGY CONSUMPTION CURRENT 232
ENERGY CONSUMPTION POTENTIAL 150
CO2 EMISSIONS CURRENT 18
CO2 EMISS CURR PER FLOOR AREA 34
CO2 EMISSIONS POTENTIAL 12
LIGHTING COST CURRENT 218
LIGHTING COST POTENTIAL 218
HEATING COST CURRENT 4113
HEATING COST POTENTIAL 2798
HOT WATER COST CURRENT 145
HOT WATER COST POTENTIAL 145
TOTAL FLOOR AREA 530
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 12
NUMBER HEATED ROOMS 12
LOW ENERGY LIGHTING 88
NUMBER OPEN FIREPLACES 2
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Full secondary glazing
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas, Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in 88% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.25
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS St. Marys House, 47, High Street, Trumpington
LOCAL AUTHORITY LABEL Cambridge
CONSTITUENCY LABEL Cambridge
POSTTOWN CAMBRIDGE
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2018-12-21 17:31:26
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 100
LOW ENERGY FIXED LIGHT COUNT 88
UPRN 200004160696
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000006
Address display
Nation ew