Energy Performance Certificate

2, Red Hall Drive, LS14 1EJ

EPC Report

Energy rating

Current: 61 D | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 60 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 60 Current: 60 91 Potential: 91
Field Value
LMK KEY 8691-3391-9529-5627-9073
ADDRESS1 2, Red Hall Drive
ADDRESS2
ADDRESS3
POSTCODE LS14 1EJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2013-10-21
LOCAL AUTHORITY E08000035
CONSTITUENCY E14001320
COUNTY
LODGEMENT DATE 2013-10-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 60
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 293
ENERGY CONSUMPTION POTENTIAL 63
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 56
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 32
HEATING COST CURRENT 501
HEATING COST POTENTIAL 358
HOT WATER COST CURRENT 100
HOT WATER COST POTENTIAL 51
TOTAL FLOOR AREA 50
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 12
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 12% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Red Hall Drive
LOCAL AUTHORITY LABEL Leeds
CONSTITUENCY LABEL Leeds East
POSTTOWN LEEDS
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2013-10-22 13:51:57
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 72167869
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew