Energy Performance Certificate

14, Charles Street, NG24 1RL

EPC Report

Energy rating

Current: 48 E | Potential: 85 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 E Current: 48 E 85 B Potential: 85 B

Environmental impact (CO₂)

Current: 41 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 83 Potential: 83
Field Value
LMK KEY 8685-6925-9140-8468-7922
ADDRESS1 14, Charles Street
ADDRESS2
ADDRESS3
POSTCODE NG24 1RL
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 48
POTENTIAL ENERGY EFFICIENCY 85
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-05-28
LOCAL AUTHORITY E07000175
CONSTITUENCY E14001375
COUNTY
LODGEMENT DATE 2015-05-28
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 406
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 72
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 1080
HEATING COST POTENTIAL 479
HOT WATER COST CURRENT 120
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 82
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Charles Street
LOCAL AUTHORITY LABEL Newark and Sherwood
CONSTITUENCY LABEL Newark
POSTTOWN NEWARK
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-05-28 18:42:24
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100031440858
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew