Energy Performance Certificate

11, Prospect Place, Skelton-in-Cleveland, TS12 2BY

EPC Report

Energy rating

Current: 20 G | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 G Current: 20 G 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 31 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 Current: 31 91 Potential: 91
Field Value
LMK KEY 8684-7723-2810-9573-6996
ADDRESS1 11, Prospect Place
ADDRESS2 Skelton-in-Cleveland
ADDRESS3
POSTCODE TS12 2BY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 20
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-07-17
LOCAL AUTHORITY E06000003
CONSTITUENCY E14001368
COUNTY
LODGEMENT DATE 2014-07-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 31
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 560
ENERGY CONSUMPTION POTENTIAL 61
CO2 EMISSIONS CURRENT 7.5
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 96
LIGHTING COST POTENTIAL 48
HEATING COST CURRENT 1520
HEATING COST POTENTIAL 394
HOT WATER COST CURRENT 490
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 11, Prospect Place, Skelton-in-Cleveland
LOCAL AUTHORITY LABEL Redcar and Cleveland
CONSTITUENCY LABEL Middlesbrough South and East Cleveland
POSTTOWN SALTBURN-BY-THE-SEA
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-07-17 16:09:46
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100110085540
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000001
Address display
Nation ew