Energy Performance Certificate

3, Parklands Drive, LA16 7JP

EPC Report

Energy rating

Current: 32 F | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 41 | Potential: 84
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 41 Current: 41 84 Potential: 84
Field Value
LMK KEY 8680-6323-7470-4620-2292
ADDRESS1 3, Parklands Drive
ADDRESS2
ADDRESS3
POSTCODE LA16 7JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2020-07-10
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001076
COUNTY
LODGEMENT DATE 2020-08-28
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 41
ENVIRONMENT IMPACT POTENTIAL 84
ENERGY CONSUMPTION CURRENT 460
ENERGY CONSUMPTION POTENTIAL 104
CO2 EMISSIONS CURRENT 5.5
CO2 EMISS CURR PER FLOOR AREA 78
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 65
LIGHTING COST POTENTIAL 65
HEATING COST CURRENT 1544
HEATING COST POTENTIAL 421
HOT WATER COST CURRENT 381
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 71
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Programmer and appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Parklands Drive
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Barrow and Furness
POSTTOWN ASKAM-IN-FURNESS
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2020-08-28 12:43:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 36027498
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew